/images/store/162/Concrete_Pour_pict.jpg/images/store/162/Concrete_Pour_Trowel_3.jpg/images/store/162/Contractor_W-Plans_6.jpg
/images/store/162/CraneSunset.jpg/images/store/162/Drywall_App_4.jpg/images/store/162/Grading_5.jpg
/images/store/162/Industrial_pict.jpg/images/store/162/Masonry_App_7.jpg/images/store/162/Masonry_pict.jpg
/images/store/162/Plywood_pict.jpg/images/store/162/Tilt-Up_Workers_App_2.jpg/images/store/162/Tilt-Up_Workers_App_4.jpg
 

Search:

Ladder 2 Wire CMU Size: 4''

Wire-Bond

(click image to enlarge)
SKU / Product InfoQuantity
WB-L2WEHD4-HDG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 3/16" CMU Size: 4'' Hot Dip Galvanized
WB-L2WEHD4-MG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 3/16" CMU Size: 4'' Mill Galvanized
WB-L2WEHD4-SS
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 3/16" CMU Size: 4'' Stainless Steel
WB-L2WHD4-HDG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 9 Gauge CMU Size: 4'' Hot Dip Galvanized
WB-L2WHD4-MG
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 9 Gauge CMU Size: 4'' Mill Galvanized
WB-L2WHD4-SS
16" O.C. Side Rods: 3/16" (.187 in) Cross Rods: 9 Gauge CMU Size: 4'' Stainless Steel
WB-L2WS4-HDG
16" O.C. Side Rods: 9 Gauge (.148 in) Cross Rods: 9 Gauge CMU Size: 4'' Hot Dip Galvanized
WB-L2WS4-MG
16" O.C. Side Rods: 9 Gauge (.148 in) Cross Rods: 9 Gauge CMU Size: 4'' Mill Galvanized
WB-L2WS4-SS
16" O.C. Side Rods: 9 Gauge (.148 in) Cross Rods: 9 Gauge CMU Size: 4'' Stainless Steel
 
Quick Overview

  • 16" O.C. ladder design positions cross rods on web of block to allow core clearance.
  • Simplifies rebar installation; centering utilizes strength of grout.
  • Allows unrestricted flow of grout or loose fill insh6ation into CMU cells.
  • Minimizes re-setting of joint reinforcement around rebar.
  • Improves resistance to shrinkage cracking.
  • Provides stronger bond with cross rods in web of block.
  • Less time devoted to rebar installation, grout pouring.
  • Meets ASCE/ACI 530 building code requirements for masonry structures and ASTM A 951 (standard specification for masonry joint reinforcing).
Interested in this item or want more information?

Phone:
Email:

Can't find what you want? Give us a call and we can help you find it.
Details
Ladder design is a prefabricated reinforcement for embedment in the horizontal mortar joints of masonry. It is manufactured in 10’ 8” lengths from wire conforming to ASTM A 82 / A82M for cold drawn steel wire. It consists of two or more parallel and deformed longitudinal wires welded to a perpendicular cross wire spaced 16" O.C. Out-to-out spacing is approximately two inches less than the nominal thickness of the wall.

Gauges:

  • Standard Weight ( 9ga x 9ga).

  • Heavy ( 3/16" Side Rods x 9ga Cross Rods).

  • Extra Heavy (3/16" Side Rods x 3/16" Cross Rods).


  • Available Finishes:

  • Mill Galvanized

  • Hot Dip Galvanized

  • Stainless Steel
  • Additional Information
    Manufacturer: Wire-Bond
     
    Search:
    Facebook GooglePlus LinkedIn StumbleUpon Twitter YouTube
     
    © 2020 48WS®.com LLC. All Rights Reserved
     
    Powered by 48ws.com